Logic Controlled Commercial Reverse Osmosis System

Commercial Reverse Osmosis System



   1800/3600/4800/6300 GPD Commercial Logic Controlled Model
*   Stainless Steel multi-stage pump
*   Stainless Steel membrane housing
*   Thin film composite TFC membrane
*   10" 5 micron sediment pre-filter
*   Liquid-filled high pressure gauge
*   NEMA 4 fiberglass enclosed electrical circuits
*   Monitor lights for power, running, low pressure, tank full
*   Electrical dual level float switch
*   Fused Off/On electrical safety switch control
*   Low pressure bypass delay
*   Time delay start
*   Salt rejection 95-99%
*  
Made with U.S. premium parts Made in USA
*   Direct from original manufacturer




 


1800-2000 gpd $4690

3600-4000 gpd $5990

4800-5600 gpd $6990

6300-7200 gpd $8290

8000-9000 gpd $9290

9500-10800 gpd $10190




 

Premium Features Equipped

  Standard Features:   Standard Electrical Controls:
 
  • Powder-coated steel frame
  • Stainless steel multi-stage pump
  • Stainless steel membrane housing
  • Thin Film Composite membrane
  • High-pressure nylon tubing
  • Liquid-filled high pressure gauge
  • Liquid-tight wire shrouding
  • Feed water inlet solenoid valve
  • Adjustable waste/recycle needle valves
  • Product and waste flow meters
  • Inlet and outlet pre-filter gauges
  • High-pressure brass comp. fittings
  • 110 volt or 220 volt-60 hz electrical supply
  •  
  • NEMA 4 fiberglass enclosure
  • Off/On switch
  • Dual level float switches
  • Low pressure switch
  • Low pressure bypass delay
  • Fused control circuit
  • 24 volt level control circuit
  • Time delay start
  • 30 amp motor contactor
  • Lights: power, running, low pressure, tank full
  •  

    This is our most durable reverse osmosis system with unmatchable value in quality, convenience, and price.
    NSF-grade high quality parts made in the U.S.A. are used to build this tough system.
    All APEC commercial RO systems are wet tested before shipment, and are delivered with individual quality assurance reports to show actual performance data on outputs and rejections.

    Optional Features

  • Tank pressure switch
  • No charge
  • TDS digital monitor, panel mount
  • $ 300
  • Recycle flow meter
  • $ 100
  • Automatic hourly flush
  • $ 280
  • High pressure cut-off w/auto restart and manual override
  • $ 350
  • Pre-treat lock-out with light
  • $ 150
  • 3phase power supply (requires IEC motor contactor)
  • $ 200
  • 50 hz electrical
  • for RO-LOGIC1800 GPD model $ 200
    for RO-LOGIC3600 GPD model $ 250
    for RO-LOGIC4800 GPD model $ 300
    for RO-LOGIC6300 GPD model $ 350
  • Shipping crate
  • $ 170

    Explanation of Standard Features:


    Stainless steel multi-stage pump:
    Sometimes referred to as a "shotgun pump", this pump uses multiple stages of impellers to create pressure for the membrane. The impellers of the pump are glass-filled Noryl with poly carbonate diffusers. The pump housing, including the inlet and outlet ports are constructed of stainless steel.

    Liquid-filled high pressure gauge:
    This gauge is filled with glycerin. The "liquid" prevents gauge needle vibration.

    Feed water inlet solenoid valve: This solenoid valve turns the water supply to the LOGIC CONTROLLED commerciall RO system OFF when the storage tank is full and turns ON when the storage tank needs more water.

    Adjustable waste/recycle needle valve, stainless steel: The waste valve controls the system operating pressure (180-200 psi). The recycle valve allows the system to recycle a portion of waste water back into the LOGIC CONTROLLED commercial RO system to obtain a higher feed flow recovery (up to 60%).

    Product and waste flow meter: These flow meters allow customer to monitor the product and waste flow rates.

    Liquid-filled inlet and outlet pre-filter gauges: These gauges monitor the pressure BEFORE and AFTER the system pre-filter. This allows the customer to know when to change out the pre-filter. A pressure differential of about 15 psi between the two gauges indicates the filter should be changed. Example: Pre-filter IN pressure is 50 psi and Pre-filter OUT psi is 35. This is a differential pressure of 15 psi.

    NEMA 4 fiberglass enclosed electrical circuits: The fiberglass enclosure contains the motor and system control circuits. NEMA 4 is an common electrical class rating for the enclosure itself.

    Dual level float switches: The dual level float switch tells the LOGIC CONTROLLED commercial RO system when to turn OFF the storage tank (tank full) and ON when the tank needs water. This switch assembly is connected to a bulkhead tank adaptor(supplied with float switch) and to be installed into the storage tank at installation site.

    Low pressure switch: This is a safety feature designed to make sure there is at least 30 psi being delivered to the LOGIC CONTROLLED commercial RO system before the motor starts. This switch protects the pump from running dry due to no feed water supply.

    Low pressure bypass delay: Typically, when the RO system pump starts, a low pressure condition can occur due to the suction of the pump. A timer in the control circuit allows the RO system to continue to run for about 10 seconds to override any low pressure shut-off condition.

    24 volt level control circuit: Low voltage is supplied to the float switches for safety reasons.

    Time delay start: A timer in the control circuit delays system start to make sure the RO system is flooded with water before the high pressure pump starts.

    30 amp contactor:
    The contactor is a switch that controls power to the motor.

    Explanation of Optional Features:

    Automatic hourly flush: This feature is a forward flow, rapid flow of water movement on the RO membrane. Flushing takes place during RO system start-up and every hour after that for 2 minute duration. Flushing helps loosen debris from the membrane surface, helping to prolong membrane life.

    TDS digital monitor: Customer may elect this option to continually monitor the Total Dissolved Solids in the product water.

    Recycle flow meter: This flow meter monitors the amount of water being recycled from the waste side of the membrane back into the inlet of the pump.

    Tank pressure switch: The LOGIC CONTROLLED commercial RO system can be set up for a pressurized water storage tank. If this option is selected, it is important that the air pressure on the storage tank is set at 25 psi.

    High pressure cut-off w/auto restart and manual override: This switch turns off the RO system if the pressure exceeds 200 psi. A timer will try to re-start the RO system every 15 minutes. This re-start timer can be over-ridden by pushing a button.

    Pre-treat lock-out with light:
    This feature is used when a customer wishes to turn off the RO system during any pre-treatment backwashing. NOTE: The pre-treatment control valves must be outfitted with a lock-out micro switch for this feature to be operational.

    3phase power supply (require IEC motor contactor): Choose this option if you want to connect the system to a 3phase power supply. With the 3phrase power supply, IEC motor contactor is required to add on because it serves as a protection to the motor.

    50 hz electrical:
    Electrical supply of 50hz is common in Europe, South America, Africa, Middle Eastern, Asia and parts of Japan. (USA electrical supply is 60hz)

    Shipping crate: Overseas shipments require extra protection. Customer will need this optional wood shipping crate.

    Commercial RO System Technical Guidelines

    Commercial reverse osmosis water treatment is quite complex because very large amounts of water are processed daily. There are many stringent requirements for the input water quality for commercial ROs compared to residential RO systems. Commercial RO systems (at over 400 GPD flow rates) would always require pre-treatment of the incoming water to assure a flawless operation and membrane/system longevity. The appropriate pre-treatment depends on local water quality. The most commonly used pre-treatments are water softeners and back-washing carbon filters for treating hard and chlorinated water. Other specialty filters can be used when specific contaminants are present. For example, if you have above 0.5 ppm of iron in your water, you would need an iron-removal filter in front of the commercial RO system.

    When sizing a system, particularly if system output is critical for you, you need to understand that the actual flow rate GPD (Gallons Per Day) of any reverse osmosis system depends on the water pressure, input water temperature and your water conditions (whether appropriate pre-treatment is applied). While the industry standard temperature is set at 77 °F, we know that not everyone has 77 °F input water. Below is a water temperature compensation chart for you to calculate the nominal GPD of your RO system at different temperatures.

    INSTRUCTIONS: find your water temperature and its factor, divide the RO system GPD by that factor, and you will get the temperature-corrected output .

    °C
    3
    5
    7
    9
    11
    13
    15
    17
    19
    21
    23
    25
    27
    29
    31
    33
    35
    37
    °F
    37.4
    41
    44.6
    48.2
    51.8
    55.4
    59
    62.6
    66.2
    69.8
    73.4
    77
    80.6
    84.2
    87.8
    91.4
    95
    98.4
    FACTOR
    3.03
    2.58
    2.22
    2
    1.78
    1.61
    1.47
    1.34
    1.24
    1.15
    1.08
    1
    0.94
    0.88
    0.83
    0.77
    0.73
    0.69


    FEED WATER REQUIREMENTS :
    OPERATING PARAMETERS :

    Temperature 85° F maximum
    pH range 3-11

    Input Pressure 40-80 psi maximum
    Operating pressure 200 psi maximum


    Hardness must be softened.

    TDS 2000 ppm maximum.

    Iron 0.5 ppm maximum.

    Turbidity should be removed.

    Hydrogen sulfide must be removed.

    Silica needs to be less than 125 ppm in the concentrate stream, anti-scalant should be considered for any levels over 75 ppm.

     


    Water recovery up to 60% and is field adjusted by customer. (Only under certain conditions can the recovery be set higher than 50%)

    Flow rates are determined by membrane manufacturer's testing criteria of 1500 ppm NaCl solution @ 77 °F water temperature and 225 psi at 10-15% recovery.

    Actual flow rates may vary depending on the pre-treatment used, water conditions, membrane array, and applied pressure.


    RO Membrane Nominal Rejection Guide

    Giardia cysts

    Criptosporidium cysts

    DDT

    PCB

    E.coli bacteria

    Fecal bacteria

    Chlorinated Pesticides

    Radium

    Arsenic (+3/ +5)

    Sodium Chloride NaCl 

    Chromium (+3 /+ 6)

    Glucose

    Sodium

    Nickel

    Chloride 

    Copper 

    Potassium

    Zinc

    Bicarbonate  

    Sulfate

    Calcium

    Silica SiO2

    Nitrate 3

    Chromate  

    Magnesium 

    Cadmium 

    Fluoride

    Barium

    Iron 

    Silver  

    Silicate 

    Ammonium 

    Aluminum 

    Mercury

    Phosphate 

    Lead


    System Specifications

    MODEL
    GPD
    MEMBRANE
    PIPING (inlet, waste, product)
    DIMENSION
    MOTOR
    RO-LOGIC 1800
    1800-2000
    4" x 40" 1 each
    1 " 1/2" 1/2"
    24" x 29" x 53"
    1.5 HP
    RO-LOGIC 3600
    3600-4000
    4" x 40" 2 each
    1 " 1/2" 1/2"
    24" x 29" x 53"
    2.0 HP
    RO-LOGIC 4800
    4800-5600
    4" x 40" 3 each
    1 " 1/2" 1/2"
    24" x 29" x 53"
    2.0 HP
    RO-LOGIC 6300
    6300-7200
    4" x 40" 4 each
    1 " 1/2" 1/2"
    29" x 29" x 56"
    3.0 HP

    = Products of Superior Performance and Dependability APEC Reverse Osmosis Made In USA
    F.A.Q.s
    Reverse Osmosis Technical Center
    Learn the Truths About Drinking Water
    Contaminants Fact Sheets
    Water Can Cure Diseases
    Water And Our Health
    Water News

    Contact APEC
    Current Promotions
    Our Reviews
    About APEC
    Refer & Get Cash
    Warranty

    Buy Online or Call 1800-880-4808 (9am-5pm PST)