APEC Plus Reverse Osmosis Commercial Systems
- 250, 450, 800 GPD Commercial Plus Model
- Super high flow Thin Film composite TFC membrane
- Liquid-filled Inlet and outlet pre-filter gauges
- Liquid-filled system pressure gauge
- Stainless steel fixed waste/recycle flow control
- Pressurized tank pressure gauge
- 20 Inch 5 micron carbon and sediment filters
- Storage tank pressure switch
- Feed water low-pressure switch
- Contaminant rejection 95-99%
- Designed, Assembled, and Lab Tested in the USA
- Direct from Original Manufacturer
- Pressurized Storage Tank Pressure Switch included
Details
Other Premium Features Equipped
- One 20 Inch 5 micron sediment pre-filter
- One 20 Inch 5 micron carbon block pre-filter
- Stainless steel membrane housing
- Super high flow Thin Film composite TFC membrane
- Powder-coated premium steel frame
- Feed water inlet solenoid valve
- High-pressure nylon tubing
- High-pressure brass comp. fittings
- 110 volt-50/60 hz
- 1/2 hp motor (3/4 hp for 800 GPD model)
- Rotary vane pump
This is our most durable reverse osmosis system with unmatched value in quality, convenience, and price. NSF-grade high quality parts are used to build this tough system. All APEC compact commercial RO systems are constructed of premium components, high quality filters and membranes to guarantee high rejection rates and output speed.
Explanation of Standard Features:
Liquid-filled system pressure gauge
This gauge is filled with glycerin. The "liquid" prevents gauge needle vibration.
Liquid-filled Inlet/Outlet pre-filter gauges
These gauges monitor the pressure BEFORE and AFTER the system pre-filters. This allows you to know when to change out the pre-filters. A pressure differential of about 15 psi between the two gauges indicates the filters should be changed. Example: Pre-filter IN pressure is 50 psi and Pre-filter OUT psi is 35. This is a differential pressure of 15 psi.
Stainless steel fixed waste/recycle flow controls
The fixed flow control devices are stainless steel flat plates with a small hole drilled in the center. This flow control feature regulates waste water and recycle flows. The COMPACT model RO system is pre-set to obtain a 50% feed flow recovery. This means that for every gallon of product water produced, 1 gallon flows to the drain. Fixed flow control makes certain the recovery rate is tamper proof.
Storage tank pressure switch
All Commercial PLUS RO models come standard with a bladder (pressurized) tank pressure switch. This means that the Commercial PLUS RO system is set up for product water to be stored in a pressurized storage tank only. If you are using an open (atmospheric) tank, you will require the optional float switch. The pressure settings on the tank pressure switch will make the Commercial PLUS RO system turn off at 50 psi and turn on at 30 psi in the pressurized storage tank.
Feed water inlet solenoid valve
This solenoid valve turns the water supply to the COMPACT RO system OFF when the storage tank is full and turns ON when the storage tank needs more water.
Feed water low pressure switch
This is a safety feature designed to make sure there is at least 30 psi being delivered to the COMPACT RO system before the motor starts. This switch protects the pump from running dry due to no feed water supply.
Rotary vane pump
This pump provides the necessary operating pressure (approx. 180 to 200 psi) to the RO membrane.
Low pressure switch
This is a safety feature designed to make sure there is at least 30 psi being delivered to the plus commercial RO system before the motor starts. This switch protects the pump from running dry due to no feed water supply.
24 volt level control circuit
Low voltage is supplied to the float switches for safety reasons.
TFC extra low energy membrane
Super high flow, high rejection and consistently performing to deliver excellent performance in terms of flux, salt and organics rejection, and microbiological resistance.
Explanation of Optional Features:
Float switch for atmospheric storage tank
If you intend to store the RO water in an atmospheric (open storage) water tank, a float switch is needed. This option cannot be used with a pressurized storage tank.
TDS digital monitor, remote mount
Customer may select this option to continually monitor the Total Dissolved Solids in the product water.
Product and waste flow meters
Monitors product and waste water flow in GPM or GPH.
220 volt/60 hz Motor
The Commercial PLUS RO system is standard 110v power. Select this option if your operation voltage is 220v.
Tank & Tank Ball Valve
Pressurized Water Storage Tank in 3 sizes (TANK-34 , TANK-44, and TANK-86) and Optional Tank Ball Valve (TBVAL1-14X3-8)
FEED WATER REQUIREMENTS:
Temperature 85 DegreeF
maximum pH range 3-11
Hardness over 10 gpg should be softened.
TDS 2000 ppm maximum.
Iron 0.5 ppm maximum.
Turbidity should be removed.
Hydrogen sulfide must be removed.
Silica needs to be less than 125 ppm in the concentrate stream, anti-scalant should be considered for any levels over 75 ppm.
OPERATING PARAMETERS:
Input Pressure 40-80 psi maximum
Operating pressure 200 psi maximum
Water recovery is factory set at 50%.
Flow rates are determined by membrane manufacturer's testing criteria of 1500 ppm NaCl solution @ 77 DegreeF water temperature and 225 psi at 10-15% recovery.
Actual flow rates may vary depending on the pre-treatment used, water conditions, membrane array, and applied pressure.
RO Membrane Nominal Rejection Guide
- Giardia cysts
- E.coli bacteria
- Arsenic (+3/ +5)
- Sodium
- Potassium
- Calcium
- Magnesium
- Iron
- Aluminum
- DDT
- Chlorinated Pesticides
- Chromium (+3 /+ 6)
- Chloride
- Bicarbonate
- Nitrate 3
- Fluoride
- Silicate
- Phosphate
- Cryptosporidium cysts
- Fecal bacteria
- Sodium Chloride NaCl
- Nickel
- Zinc
- Silica SiO2
- Cadmium
- Silver
- Mercury
- PCB
- Radium
- Glucose
- Copper
- Sulfate
- Chromate
- Barium
- Ammonium
- Lead
Commercial RO System Technical Guidelines
Commercial reverse osmosis water treatment is quite complex because very large amounts of water are processed daily. There are many stringent requirements for the input water quality for commercial ROs compared to residential RO systems. Commercial RO systems (at over 400 GPD flow rates) would always require pre-treatment of the incoming water to assure a flawless operation and membrane/system longevity. The appropriate pre-treatment depends on local water quality. The most commonly used pre-treatments are water softeners and back-washing carbon filters for treating hard and chlorinated water. Other specialty filters can be used when specific contaminants are present. For example, if you have above 0.5 ppm of iron in your water, you would need an iron-removal filter in front of the commercial RO system.
When sizing a system, particularly if system output is critical for you, you need to understand that the actual flow rate GPD (Gallons Per Day) of any reverse osmosis system depends on the water pressure, input water temperature and your water conditions (whether appropriate pre-treatment is applied). While the industry standard temperature is set at 77 °F, we know that not everyone has 77 °F input water. Below is a water temperature compensation chart for you to calculate the nominal GPD of your RO system at different temperatures.
INSTRUCTIONS: find your water temperature and its factor, divide the RO system GPD by that factor, and you will get the temperature-corrected output.
ºC
ºF
Factor
3
37.4
3.03
5
41
2.58
7
44.6
2.22
9
48.2
2.00
11
51.8
1.78
13
55.4
1.61
15
59
1.47
17
62.6
1.34
19
66.2
1.24
21
69.8
1.15
23
73.4
1.08
25
77
1.00
27
80.6
0.94
29
84.2
0.88
31
87.8
0.83
33
91.4
0.77
35
95
0.73
37
98.4
0.69
System Specifications
MODEL
RO-PLUS 250
RO-PLUS 450
RO-PLUS 800
System Output (GPD)
250
450
800
RO Membrane
2.5" X 21" 1 each
MEM-XLE-250
4" X 14" 1 each
MEM-450-XLE-AWT
4" X 21" 1 each
MEM-XLE-800
System Connection Size (inlet, waste, product)
1/2" x 3/8" x 3/8"
1/2" x 3/8" x 3/8"
1/2" x 3/8" x 3/8"
System Dimensions
14" x 16" x 30"H
14" x 16" x 30"H
14" x 16" x 30"H
System Weight
88 lbs
92 lbs
95 lbs
More information
Commercial RO System Technical Guidelines
Commercial reverse osmosis water treatment is quite complex because very large amounts of water are processed daily. There are many stringent requirements for the input water quality for commercial ROs compared to residential RO systems. Commercial RO systems (at over 400 GPD flow rates) would always require pre-treatment of the incoming water to assure a flawless operation and membrane/system longevity. The appropriate pre-treatment depends on local water quality. The most commonly used pre-treatments are water softeners and back-washing carbon filters for treating hard and chlorinated water. Other specialty filters can be used when specific contaminants are present. For example, if you have above 0.5 ppm of iron in your water, you would need an iron-removal filter in front of the commercial RO system.
When sizing a system, particularly if system output is critical for you, you need to understand that the actual flow rate GPD (Gallons Per Day) of any reverse osmosis system depends on the water pressure, input water temperature and your water conditions (whether appropriate pre-treatment is applied). While the industry standard temperature is set at 77 °F, we know that not everyone has 77 °F input water. Below is a water temperature compensation chart for you to calculate the nominal GPD of your RO system at different temperatures.
INSTRUCTIONS: find your water temperature and its factor, divide the RO system GPD by that factor, and you will get the temperature-corrected output.
ºC
ºF
Factor
3
37.4
3.03
5
41
2.58
7
44.6
2.22
9
48.2
2.00
11
51.8
1.78
13
55.4
1.61
15
59
1.47
17
62.6
1.34
19
66.2
1.24
21
69.8
1.15
23
73.4
1.08
25
77
1.00
27
80.6
0.94
29
84.2
0.88
31
87.8
0.83
33
91.4
0.77
35
95
0.73
37
98.4
0.69
System Specifications
MODEL
RO-PLUS 250
RO-PLUS 450
RO-PLUS 800
System Output (GPD)
250
450
800
RO Membrane
2.5" X 21" 1 each
MEM-XLE-250
4" X 14" 1 each
MEM-450-XLE-AWT
4" X 21" 1 each
MEM-XLE-800
System Connection Size (inlet, waste, product)
1/2" x 3/8" x 3/8"
1/2" x 3/8" x 3/8"
1/2" x 3/8" x 3/8"
System Dimensions
14" x 16" x 30"H
14" x 16" x 30"H
14" x 16" x 30"H
System Weight
88 lbs
92 lbs
95 lbs
Shipping & Returns
We are proud to offer 1 day order processing (excluding weekends and holidays). Orders that are placed prior to 12:00 pm PST with express shipping services will be guaranteed to ship out the same day – subject to order verification and credit approval. Our shipping charges are based on the method of service and the location.
Products can be returned within 30 days from the date of invoice. Please carefully review APEC's Return Policy details and conditions.
Other Premium Features Equipped
- One 20 Inch 5 micron sediment pre-filter
- One 20 Inch 5 micron carbon block pre-filter
- Stainless steel membrane housing
- Super high flow Thin Film composite TFC membrane
- Powder-coated premium steel frame
- Feed water inlet solenoid valve
- High-pressure nylon tubing
- High-pressure brass comp. fittings
- 110 volt-50/60 hz
- 1/2 hp motor (3/4 hp for 800 GPD model)
- Rotary vane pump
This is our most durable reverse osmosis system with unmatched value in quality, convenience, and price. NSF-grade high quality parts are used to build this tough system. All APEC compact commercial RO systems are constructed of premium components, high quality filters and membranes to guarantee high rejection rates and output speed.
Explanation of Standard Features:
Liquid-filled system pressure gauge
This gauge is filled with glycerin. The "liquid" prevents gauge needle vibration.
Liquid-filled Inlet/Outlet pre-filter gauges
These gauges monitor the pressure BEFORE and AFTER the system pre-filters. This allows you to know when to change out the pre-filters. A pressure differential of about 15 psi between the two gauges indicates the filters should be changed. Example: Pre-filter IN pressure is 50 psi and Pre-filter OUT psi is 35. This is a differential pressure of 15 psi.
Stainless steel fixed waste/recycle flow controls
The fixed flow control devices are stainless steel flat plates with a small hole drilled in the center. This flow control feature regulates waste water and recycle flows. The COMPACT model RO system is pre-set to obtain a 50% feed flow recovery. This means that for every gallon of product water produced, 1 gallon flows to the drain. Fixed flow control makes certain the recovery rate is tamper proof.
Storage tank pressure switch
All Commercial PLUS RO models come standard with a bladder (pressurized) tank pressure switch. This means that the Commercial PLUS RO system is set up for product water to be stored in a pressurized storage tank only. If you are using an open (atmospheric) tank, you will require the optional float switch. The pressure settings on the tank pressure switch will make the Commercial PLUS RO system turn off at 50 psi and turn on at 30 psi in the pressurized storage tank.
Feed water inlet solenoid valve
This solenoid valve turns the water supply to the COMPACT RO system OFF when the storage tank is full and turns ON when the storage tank needs more water.
Feed water low pressure switch
This is a safety feature designed to make sure there is at least 30 psi being delivered to the COMPACT RO system before the motor starts. This switch protects the pump from running dry due to no feed water supply.
Rotary vane pump
This pump provides the necessary operating pressure (approx. 180 to 200 psi) to the RO membrane.
Low pressure switch
This is a safety feature designed to make sure there is at least 30 psi being delivered to the plus commercial RO system before the motor starts. This switch protects the pump from running dry due to no feed water supply.
24 volt level control circuit
Low voltage is supplied to the float switches for safety reasons.
TFC extra low energy membrane
Super high flow, high rejection and consistently performing to deliver excellent performance in terms of flux, salt and organics rejection, and microbiological resistance.
Explanation of Optional Features:
Float switch for atmospheric storage tank
If you intend to store the RO water in an atmospheric (open storage) water tank, a float switch is needed. This option cannot be used with a pressurized storage tank.
TDS digital monitor, remote mount
Customer may select this option to continually monitor the Total Dissolved Solids in the product water.
Product and waste flow meters
Monitors product and waste water flow in GPM or GPH.
220 volt/60 hz Motor
The Commercial PLUS RO system is standard 110v power. Select this option if your operation voltage is 220v.
Tank & Tank Ball Valve
Pressurized Water Storage Tank in 3 sizes (TANK-34 , TANK-44, and TANK-86) and Optional Tank Ball Valve (TBVAL1-14X3-8)
FEED WATER REQUIREMENTS:
Temperature 85 DegreeF
maximum pH range 3-11
Hardness over 10 gpg should be softened.
TDS 2000 ppm maximum.
Iron 0.5 ppm maximum.
Turbidity should be removed.
Hydrogen sulfide must be removed.
Silica needs to be less than 125 ppm in the concentrate stream, anti-scalant should be considered for any levels over 75 ppm.
OPERATING PARAMETERS:
Input Pressure 40-80 psi maximum
Operating pressure 200 psi maximum
Water recovery is factory set at 50%.
Flow rates are determined by membrane manufacturer's testing criteria of 1500 ppm NaCl solution @ 77 DegreeF water temperature and 225 psi at 10-15% recovery.
Actual flow rates may vary depending on the pre-treatment used, water conditions, membrane array, and applied pressure.
RO Membrane Nominal Rejection Guide
- Giardia cysts
- E.coli bacteria
- Arsenic (+3/ +5)
- Sodium
- Potassium
- Calcium
- Magnesium
- Iron
- Aluminum
- DDT
- Chlorinated Pesticides
- Chromium (+3 /+ 6)
- Chloride
- Bicarbonate
- Nitrate 3
- Fluoride
- Silicate
- Phosphate
- Cryptosporidium cysts
- Fecal bacteria
- Sodium Chloride NaCl
- Nickel
- Zinc
- Silica SiO2
- Cadmium
- Silver
- Mercury
- PCB
- Radium
- Glucose
- Copper
- Sulfate
- Chromate
- Barium
- Ammonium
- Lead
Commercial RO System Technical Guidelines
Commercial reverse osmosis water treatment is quite complex because very large amounts of water are processed daily. There are many stringent requirements for the input water quality for commercial ROs compared to residential RO systems. Commercial RO systems (at over 400 GPD flow rates) would always require pre-treatment of the incoming water to assure a flawless operation and membrane/system longevity. The appropriate pre-treatment depends on local water quality. The most commonly used pre-treatments are water softeners and back-washing carbon filters for treating hard and chlorinated water. Other specialty filters can be used when specific contaminants are present. For example, if you have above 0.5 ppm of iron in your water, you would need an iron-removal filter in front of the commercial RO system.
When sizing a system, particularly if system output is critical for you, you need to understand that the actual flow rate GPD (Gallons Per Day) of any reverse osmosis system depends on the water pressure, input water temperature and your water conditions (whether appropriate pre-treatment is applied). While the industry standard temperature is set at 77 °F, we know that not everyone has 77 °F input water. Below is a water temperature compensation chart for you to calculate the nominal GPD of your RO system at different temperatures.
INSTRUCTIONS: find your water temperature and its factor, divide the RO system GPD by that factor, and you will get the temperature-corrected output.
ºC
ºF
Factor
3
37.4
3.03
5
41
2.58
7
44.6
2.22
9
48.2
2.00
11
51.8
1.78
13
55.4
1.61
15
59
1.47
17
62.6
1.34
19
66.2
1.24
21
69.8
1.15
23
73.4
1.08
25
77
1.00
27
80.6
0.94
29
84.2
0.88
31
87.8
0.83
33
91.4
0.77
35
95
0.73
37
98.4
0.69
System Specifications
MODEL
RO-PLUS 250
RO-PLUS 450
RO-PLUS 800
System Output (GPD)
250
450
800
RO Membrane
2.5" X 21" 1 each
MEM-XLE-250
4" X 14" 1 each
MEM-450-XLE-AWT
4" X 21" 1 each
MEM-XLE-800
System Connection Size (inlet, waste, product)
1/2" x 3/8" x 3/8"
1/2" x 3/8" x 3/8"
1/2" x 3/8" x 3/8"
System Dimensions
14" x 16" x 30"H
14" x 16" x 30"H
14" x 16" x 30"H
System Weight
88 lbs
92 lbs
95 lbs
Commercial RO System Technical Guidelines
Commercial reverse osmosis water treatment is quite complex because very large amounts of water are processed daily. There are many stringent requirements for the input water quality for commercial ROs compared to residential RO systems. Commercial RO systems (at over 400 GPD flow rates) would always require pre-treatment of the incoming water to assure a flawless operation and membrane/system longevity. The appropriate pre-treatment depends on local water quality. The most commonly used pre-treatments are water softeners and back-washing carbon filters for treating hard and chlorinated water. Other specialty filters can be used when specific contaminants are present. For example, if you have above 0.5 ppm of iron in your water, you would need an iron-removal filter in front of the commercial RO system.
When sizing a system, particularly if system output is critical for you, you need to understand that the actual flow rate GPD (Gallons Per Day) of any reverse osmosis system depends on the water pressure, input water temperature and your water conditions (whether appropriate pre-treatment is applied). While the industry standard temperature is set at 77 °F, we know that not everyone has 77 °F input water. Below is a water temperature compensation chart for you to calculate the nominal GPD of your RO system at different temperatures.
INSTRUCTIONS: find your water temperature and its factor, divide the RO system GPD by that factor, and you will get the temperature-corrected output.
ºC
ºF
Factor
3
37.4
3.03
5
41
2.58
7
44.6
2.22
9
48.2
2.00
11
51.8
1.78
13
55.4
1.61
15
59
1.47
17
62.6
1.34
19
66.2
1.24
21
69.8
1.15
23
73.4
1.08
25
77
1.00
27
80.6
0.94
29
84.2
0.88
31
87.8
0.83
33
91.4
0.77
35
95
0.73
37
98.4
0.69
System Specifications
MODEL
RO-PLUS 250
RO-PLUS 450
RO-PLUS 800
System Output (GPD)
250
450
800
RO Membrane
2.5" X 21" 1 each
MEM-XLE-250
4" X 14" 1 each
MEM-450-XLE-AWT
4" X 21" 1 each
MEM-XLE-800
System Connection Size (inlet, waste, product)
1/2" x 3/8" x 3/8"
1/2" x 3/8" x 3/8"
1/2" x 3/8" x 3/8"
System Dimensions
14" x 16" x 30"H
14" x 16" x 30"H
14" x 16" x 30"H
System Weight
88 lbs
92 lbs
95 lbs
We are proud to offer 1 day order processing (excluding weekends and holidays). Orders that are placed prior to 12:00 pm PST with express shipping services will be guaranteed to ship out the same day – subject to order verification and credit approval. Our shipping charges are based on the method of service and the location.
Products can be returned within 30 days from the date of invoice. Please carefully review APEC's Return Policy details and conditions.