The causes to the output problem are listed in the timeframe that you've owned your RO system. The grey background applies to systems in use for under 3 months and the white background applies to systems in use for more than 3 months. The causes are listed from the most frequent and probable to the least likeliest. |
Causes
|
Identify
|
Solution
|
||
1
|
Feed water blocked
|
Make sure all lines to the RO system and within the RO head are not obstructed
|
Untangles the lines
|
|
2
|
Input pressure too low
|
If your home pressure is within the model's regulation. Make sure you have the right model
|
Make sure the feed valve is fully turned on or exchange for the appropriate model
|
|
3
|
Wrong Line Installation
|
Using RO pictures and the owner's manual. Make sure all lines are correctly connected
|
||
4
|
Defective Membrane Housing (Extremely Rare) |
Waste water flows non stop down the drain line and no RO water.
|
Replace the membrane housing, Contact Us
|
|
5
|
Clogged Pre-filters
|
See the condition of the first stage filter
|
||
6
|
Clogged Membrane
|
Use TDS meter to measure the TDS
|
||
7
|
ASO Clogged
|
|||
8
|
Check valve clogged
|
Test the check valve
|
Replace the Check Valve
|
|
9
|
No Tank pressure
|
An empty 4 gallon tank should have 5 psi and empty 14 gallon tank should 7 psi |
||
10
|
Tank bladder ruptured
|
Locate the pressure valve on the tank to see if water is leaking out. If water is leaking out, then the tank needs to be replaced. Furthermore, a raptured tank tends to be very heavy compared to regular full tank.
|